The currently listed dotclock disagrees with the currently listed vrefresh rate. Change the dotclock to match the vrefresh. There are two variants of the COM37H3M panel. The older one's COM37H3M05DTC data sheet specifies: MIN TYP MAX CLK frequency fCLK -- 22.4 26.3 MHz (in VGA mode) VSYNC Frequency fVSYNC 54 60 66 Hz VSYNC cycle time tv -- 650 -- H HSYNC frequency fHSYNC -- 39.3 -- kHz HSYNC cycle time th -- 570 -- CLK The newer one's COM37H3M99DTC data sheet says: MIN TYP MAX CLK frequency fCLK 18 19.8 27 MHz VSYNC Frequency fVSYNC 54 60 66 Hz VSYNC cycle time tv 646 650 700 H HSYNC frequency fHSYNC -- 39.0 50.0 kHz HSYNC cycle time th 504 508 630 CLK So we choose a parameter set that lies within the specs of both variants. We start at .vrefresh = 60, choose .htotal = 570 and .vtotal = 650 and end up in a clock of 22.230 MHz. Reported-by: Ville Syrjala <ville.syrjala@linux.intel.com> Signed-off-by: H. Nikolaus Schaller <hns@goldelico.com> Reviewed-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Signed-off-by: Sam Ravnborg <sam@ravnborg.org> Link: https://patchwork.freedesktop.org/patch/msgid/e63a0533ad5b5142373437ef758aedbdb716152d.1583826198.git.hns@goldelico.com