Thomas Zimmermann authored
Move the BMC-related code into its own file and wire it up with device callbacks. While programming a new display mode, G200EW3 and G200WB have to de- synchronize with the BMC. Synchronization is done via VIDRST pins and controlled via VRSTEN and HRSTEN bits. Move the BMC code behind a serviceable interface and call it from the CRTC's enable and disable functions. Signed-off-by: Thomas Zimmermann <tzimmermann@suse.de> Reviewed-by: Jocelyn Falempe <jfalempe@redhat.com> Tested-by: Jocelyn Falempe <jfalempe@redhat.com> Acked-by: Sam Ravnborg <sam@ravnborg.org> Link: https://patchwork.freedesktop.org/patch/msgid/20220728124103.30159-11-tzimmermann@suse.de
8aeeb314