Guenter Roeck authored
commit 145e74a4 upstream. Upper limit for write operations to temperature limit registers was clamped to a fractional value. However, limit registers do not support fractional values. As a result, upper limits of 127.5 degrees C or higher resulted in a rounded limit of 128 degrees C. Since limit registers are signed, this was stored as -128 degrees C. Clamp limits to (-55, +127) degrees C to solve the problem. Value on writes to auto_temp[12]_min and auto_temp[12]_max were not clamped at all, but masked. As a result, out-of-range writes resulted in a more or less arbitrary limit. Clamp those attributes to (0, 127) degrees C for more predictable results. Cc: Axel Lin <axel.lin@ingics.com> Reviewed-by: Jean Delvare <jdelvare@suse.de> Signed-off-by: Guenter Roeck <linux@roeck-us.net> [bwh: Backported to 3.2: - Adjust context - Driver was using SENSORS_LIMIT(), which we can replace with clamp_val()] Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
a5931b2e