Fabrice Gasnier authored
Remove the following warnings seen when building with W=1. Warning (unique_unit_address): /soc/timer@40000c00: duplicate unit-address (also used in node /soc/timers@40000c00) This approach is based on some discussions[1], to restructure the dtsi and dts files. Timer5 is enabled by default on stm32f4 series, to act as clockevent. In order to get rid of the W=1 warning, and be compliant with dt-schemas (e.g. dtbs_check): - In stm32f429.dtsi: . Keep the more complete timers5 description . Remove the most simple timer5 node that is duplicate - In each board: . adopt "st,stm32-timer" compatible for timers5, also add the interrupt . use /delete-property/ and /delete-node/ so the it matches the clockevent bindings Note: all this is done in one shot (e.g. not split) to keep clockevent functionality. [1] https://lore.kernel.org/linux-arm-kernel/Yaf4jiZIp8+ndaXs@robh.at.kernel.org/Signed-off-by:
Fabrice Gasnier <fabrice.gasnier@foss.st.com> Signed-off-by:
Alexandre Torgue <alexandre.torgue@foss.st.com>
b380a2d1