Jani Nikula authored
Fix several issues with DSC power domains that did not take DSI transcoders into account: - On TGL+ we need to use PW2 for DSC on pipe A, not transcoder A. There is no longer an eDP transcoder, but there are two DSI transcoders which may be connected to pipe A. - On TGL+ we need to use the pipe, not transcoder, power domains for DSC on pipes other than A. Again, there are DSI transcoders. - On ICL we need to use PW2 for DSC also for DSI transcoders, not just for the eDP transcoder. Using is_pipe_dsc() also adds the warning about ICL pipe A DSC, which does not exist. Cc: José Roberto de Souza <jose.souza@intel.com> Cc: Manasi Navare <manasi.d.navare@intel.com> Cc: Vandita Kulkarni <vandita.kulkarni@intel.com> Reviewed-by: Vandita Kulkarni <vandita.kulkarni@intel.com> Signed-off-by: Jani Nikula <jani.nikula@intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20191212134728.18432-1-jani.nikula@intel.com
cabeacd4