Dean Luick authored
When reading multiple dc8051 data memory locations at once, the read enabled field must be toggled at every address change. Do that by writing only the address first, then writing the enable. Reviewed-by: Ira Weiny <ira.weiny@intel.com> Reviewed-by: Dennis Dalessandro <dennis.dalessandro@intel.com> Signed-off-by: Dean Luick <dean.luick@intel.com> Signed-off-by: Dennis Dalessandro <dennis.dalessandro@intel.com> Signed-off-by: Doug Ledford <dledford@redhat.com>
d7cf4ccf