Krzysztof Mazur authored
The br2684 does not check if used vcc is in connected state, causing potential Oops in pppoatm_send() when vcc->send() is called on not fully connected socket. Now br2684 can be assigned only on connected sockets; otherwise -EINVAL error is returned. Signed-off-by: Krzysztof Mazur <krzysiek@podlesie.net> Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
9eba2526