Aleksander Morgado authored
commit 45ba2154 upstream. When a control transfer has a short data stage, the xHCI controller generates two transfer events: a COMP_SHORT_TX event that specifies the untransferred amount, and a COMP_SUCCESS event. But when the data stage is not short, only the COMP_SUCCESS event occurs. Therefore, xhci-hcd must set urb->actual_length to urb->transfer_buffer_length while processing the COMP_SUCCESS event, unless urb->actual_length was set already by a previous COMP_SHORT_TX event. The driver checks this by seeing whether urb->actual_length == 0, but this alone is the wrong test, as it is entirely possible for a short transfer to have an urb->actual_length = 0. This patch changes the xhci driver to rely on a new td->urb_length_set flag, which is set to true when a COMP_SHORT_TX event is received and the URB length updated at that stage. This fixes a bug which affected the HSO plugin, which relies on URBs with urb->actual_length == 0 to halt re-submitting the RX URB in the control endpoint. Signed-off-by: Aleksander Morgado <aleksander@aleksander.es> Signed-off-by: Mathias Nyman <mathias.nyman@linux.intel.com> Signed-off-by: Jiri Slaby <jslaby@suse.cz>
f2a7b61c