Fenglin Wu authored
The flash module has status bits to indicate different thermal conditions which are called as OTSTx. For each OTSTx status, there is a recommended total flash current for all channels to prevent the flash module entering into higher thermal level. For example, the total flash current should be limited to 1000mA/500mA respectively when the HW reaches the OTST1/OTST2 thermal level. Signed-off-by: Fenglin Wu <quic_fenglinw@quicinc.com> Link: https://lore.kernel.org/r/20240705-qcom_flash_thermal_derating-v3-1-8e2e2783e3a6@quicinc.comSigned-off-by: Lee Jones <lee@kernel.org>
a0864cf3