Commit 02f15e4b authored by Niklas Söderlund's avatar Niklas Söderlund Committed by Simon Horman

arm64: dts: renesas: r8a7795: decrease temperature hysteresis

To incorporate more tests by the hardware team decrease the hysteresis
value to 1C.
Signed-off-by: default avatarNiklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
parent c4e96f74
......@@ -2437,12 +2437,12 @@ sensor_thermal1: sensor-thermal1 {
trips {
sensor1_passive: sensor1-passive {
temperature = <95000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "passive";
};
sensor1_crit: sensor1-crit {
temperature = <120000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "critical";
};
};
......@@ -2463,12 +2463,12 @@ sensor_thermal2: sensor-thermal2 {
trips {
sensor2_passive: sensor2-passive {
temperature = <95000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "passive";
};
sensor2_crit: sensor2-crit {
temperature = <120000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "critical";
};
};
......@@ -2489,12 +2489,12 @@ sensor_thermal3: sensor-thermal3 {
trips {
sensor3_passive: sensor3-passive {
temperature = <95000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "passive";
};
sensor3_crit: sensor3-crit {
temperature = <120000>;
hysteresis = <2000>;
hysteresis = <1000>;
type = "critical";
};
};
......
Markdown is supported