i2c: meson: set clock divider in probe instead of setting it for each transfer
The bus frequency is fixed to what is set DT, therefore we can set the clock divider in probe already and we don't have to set it for each transfer. Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com> Signed-off-by: Wolfram Sang <wsa@the-dreams.de>