ASoC: tlv320aic31xx: Reset registers during power up
Add a reset function that toggles the reset line if available or uses the software reset command otherwise. Use this in power up to ensure the registers are in a sane state. This is useful when the driver module is reloaded, or after Kexec, warm-reboots, etc.. Signed-off-by: Andrew F. Davis <afd@ti.com> Signed-off-by: Mark Brown <broonie@kernel.org>