Commit 0df13847 authored by Swen Schillig's avatar Swen Schillig Committed by James Bottomley

[SCSI] zfcp: Fix adapter activation on link down

If an exchange config is executed while the local link is down, the
request succeeds but the returned data is incomplete.  Proceeding with
the adapter activation is leading to an unpredictable behaviour (e.g.
kernel panic) caused by invalid values.  In such a scenario the
recommended ERP is to retry the action and wait for a link up event.
If the issue persists the activation has to fail.
Signed-off-by: default avatarSwen Schillig <swen@vnet.ibm.com>
Sigend-off-by: default avatarChristof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: default avatarJames Bottomley <James.Bottomley@suse.de>
parent 229aebb8
......@@ -532,9 +532,6 @@ static void zfcp_fsf_exchange_config_data_handler(struct zfcp_fsf_req *req)
fc_host_port_type(shost) = FC_PORTTYPE_UNKNOWN;
adapter->hydra_version = 0;
atomic_set_mask(ZFCP_STATUS_ADAPTER_XCONFIG_OK,
&adapter->status);
zfcp_fsf_link_down_info_eval(req,
&qtcb->header.fsf_status_qual.link_down_info);
break;
......