Commit 1116d5a7 authored by Jon Hunter's avatar Jon Hunter Committed by Thierry Reding

clk: tegra: Don't reset PLL-CX if it is already enabled

Commit 8dce89a1 ("clk: tegra: Don't warn for PLL defaults
unnecessarily") changed the tegra210_pllcx_set_defaults() function
causing the PLL to always be reset regardless of whether it is in-use.
This function was changed so that resetting of the PLL will only be
skipped if the PLL is enabled AND 'pllcx->params->defaults_set' is not
true. However, the 'pllcx->params->defaults_set' is always true and
hence, the PLL is now always reset. This causes the boot to fail on the
Tegra210 Smaug where the PLL is already enabled and in-use. Fix this by
only resetting the PLL if not in-use and only printing the warning that
the defaults are not set after we have checked the default settings.

Fixes: 8dce89a1 ("clk: tegra: Don't warn for PLL defaults unnecessarily")
Signed-off-by: default avatarJon Hunter <jonathanh@nvidia.com>
Acked-By: default avatarPeter De Schrijver <pdeschrijver@nvidia.com>
Signed-off-by: default avatarThierry Reding <treding@nvidia.com>
parent 88da44c5
......@@ -555,12 +555,12 @@ static void tegra210_pllcx_set_defaults(const char *name,
{
pllcx->params->defaults_set = true;
if (readl_relaxed(clk_base + pllcx->params->base_reg) &
PLL_ENABLE && !pllcx->params->defaults_set) {
if (readl_relaxed(clk_base + pllcx->params->base_reg) & PLL_ENABLE) {
/* PLL is ON: only check if defaults already set */
pllcx_check_defaults(pllcx->params);
pr_warn("%s already enabled. Postponing set full defaults\n",
name);
if (!pllcx->params->defaults_set)
pr_warn("%s already enabled. Postponing set full defaults\n",
name);
return;
}
......