clk: tegra: Don't reset PLL-CX if it is already enabled
Commit 8dce89a1 ("clk: tegra: Don't warn for PLL defaults unnecessarily") changed the tegra210_pllcx_set_defaults() function causing the PLL to always be reset regardless of whether it is in-use. This function was changed so that resetting of the PLL will only be skipped if the PLL is enabled AND 'pllcx->params->defaults_set' is not true. However, the 'pllcx->params->defaults_set' is always true and hence, the PLL is now always reset. This causes the boot to fail on the Tegra210 Smaug where the PLL is already enabled and in-use. Fix this by only resetting the PLL if not in-use and only printing the warning that the defaults are not set after we have checked the default settings. Fixes: 8dce89a1 ("clk: tegra: Don't warn for PLL defaults unnecessarily") Signed-off-by: Jon Hunter <jonathanh@nvidia.com> Acked-By: Peter De Schrijver <pdeschrijver@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>