Commit 1b9d8bd6 authored by Matthias Kaehlcke's avatar Matthias Kaehlcke Committed by Andy Gross

arm64: dts: qcom: pm8998: Add pm8998 thermal zone

The thermal zone uses spmi-temp-alarm as sensor, the trip points
correspond to the PMIC thermal stages 1 and 2. The critical trip
point at 125°C disables the partial PMIC shutdown at stage 2.

Without an IIO input the sensor only reports a limited number of
temperatures:

- 37°C for temperatures below 105°C
- 107°C for temperatures >= 105°C and < 125°C
- 127°C for temperatures >= 125°C

(the numbers correspond to a stage 1 threshold of 105°C)
Signed-off-by: default avatarMatthias Kaehlcke <mka@chromium.org>
Reviewed-by: default avatarDouglas Anderson <dianders@chromium.org>
Signed-off-by: default avatarAndy Gross <andy.gross@linaro.org>
parent 104e6415
...@@ -5,7 +5,31 @@ ...@@ -5,7 +5,31 @@
#include <dt-bindings/input/linux-event-codes.h> #include <dt-bindings/input/linux-event-codes.h>
#include <dt-bindings/interrupt-controller/irq.h> #include <dt-bindings/interrupt-controller/irq.h>
#include <dt-bindings/spmi/spmi.h> #include <dt-bindings/spmi/spmi.h>
#include <dt-bindings/thermal/thermal.h>
/ {
thermal-zones {
pm8998 {
polling-delay-passive = <250>;
polling-delay = <1000>;
thermal-sensors = <&pm8998_temp>;
trips {
pm8998_alert0: pm8998-alert0 {
temperature = <105000>;
hysteresis = <2000>;
type = "passive";
};
pm8998_crit: pm8998-crit {
temperature = <125000>;
hysteresis = <2000>;
type = "critical";
};
};
};
};
};
&spmi_bus { &spmi_bus {
pm8998_lsid0: pmic@0 { pm8998_lsid0: pmic@0 {
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!