e1000e: clear REQ and GNT in EECD (82571 && 82572)

Clear the REQ and GNT bit in the eeprom control register (EECD).
This is required if the eeprom is to be accessed with auto read
EERD register.

After a cold reset this doesn't matter but if PBIST MAC test was
executed before booting, the register was left in a dirty state
(the 2 bits where set), which caused the read operation to time out
and returning 0.

Reference (page 312):
http://download.intel.com/design/network/manuals/316080.pdfReported-by: default avatarAleksandar Igic <aleksandar.igic@dektech.com.au>
Signed-off-by: default avatarRichard Alpe <richard.alpe@ericsson.com>
Tested-by: default avatarJeff Pieper <jeffrey.e.pieper@intel.com>
Signed-off-by: default avatarJeff Kirsher <jeffrey.t.kirsher@intel.com>
parent 7b9f7e35
...@@ -999,7 +999,7 @@ static s32 e1000_set_d0_lplu_state_82571(struct e1000_hw *hw, bool active) ...@@ -999,7 +999,7 @@ static s32 e1000_set_d0_lplu_state_82571(struct e1000_hw *hw, bool active)
**/ **/
static s32 e1000_reset_hw_82571(struct e1000_hw *hw) static s32 e1000_reset_hw_82571(struct e1000_hw *hw)
{ {
u32 ctrl, ctrl_ext; u32 ctrl, ctrl_ext, eecd;
s32 ret_val; s32 ret_val;
/* /*
...@@ -1072,6 +1072,16 @@ static s32 e1000_reset_hw_82571(struct e1000_hw *hw) ...@@ -1072,6 +1072,16 @@ static s32 e1000_reset_hw_82571(struct e1000_hw *hw)
*/ */
switch (hw->mac.type) { switch (hw->mac.type) {
case e1000_82571:
case e1000_82572:
/*
* REQ and GNT bits need to be cleared when using AUTO_RD
* to access the EEPROM.
*/
eecd = er32(EECD);
eecd &= ~(E1000_EECD_REQ | E1000_EECD_GNT);
ew32(EECD, eecd);
break;