Commit 227a3a2f authored by Eliav Farber's avatar Eliav Farber Committed by Guenter Roeck

hwmon: (mr75203) fix voltage equation for negative source input

According to Moortec Embedded Voltage Monitor (MEVM) series 3 data
sheet, the minimum input signal is -100mv and maximum input signal
is +1000mv.

The equation used to convert the digital word to voltage uses mixed
types (*val signed and n unsigned), and on 64 bit machines also has
different size, since sizeof(u32) = 4 and sizeof(long) = 8.

So when measuring a negative input, n will be small enough, such that
PVT_N_CONST * n < PVT_R_CONST, and the result of
(PVT_N_CONST * n - PVT_R_CONST) will overflow to a very big positive
32 bit number. Then when storing the result in *val it will be the same
value just in 64 bit (instead of it representing a negative number which
will what happen when sizeof(long) = 4).

When -1023 <= (PVT_N_CONST * n - PVT_R_CONST) <= -1
dividing the number by 1024 should result of in 0, but because ">> 10"
is used, and the sign bit is used to fill the vacated bit positions, it
results in -1 (0xf...fffff) which is wrong.

This change fixes the sign problem and supports negative values by
casting n to long and replacing the shift right with div operation.

Fixes: 9d823351 ("hwmon: Add hardware monitoring driver for Moortec MR75203 PVT controller")
Signed-off-by: default avatarEliav Farber <farbere@amazon.com>
Reviewed-by: default avatarAndy Shevchenko <andriy.shevchenko@linux.intel.com>
Link: https://lore.kernel.org/r/20220908152449.35457-5-farbere@amazon.comSigned-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent bb9195bd
...@@ -201,8 +201,18 @@ static int pvt_read_in(struct device *dev, u32 attr, int channel, long *val) ...@@ -201,8 +201,18 @@ static int pvt_read_in(struct device *dev, u32 attr, int channel, long *val)
return ret; return ret;
n &= SAMPLE_DATA_MSK; n &= SAMPLE_DATA_MSK;
/* Convert the N bitstream count into voltage */ /*
*val = (PVT_N_CONST * n - PVT_R_CONST) >> PVT_CONV_BITS; * Convert the N bitstream count into voltage.
* To support negative voltage calculation for 64bit machines
* n must be cast to long, since n and *val differ both in
* signedness and in size.
* Division is used instead of right shift, because for signed
* numbers, the sign bit is used to fill the vacated bit
* positions, and if the number is negative, 1 is used.
* BIT(x) may not be used instead of (1 << x) because it's
* unsigned.
*/
*val = (PVT_N_CONST * (long)n - PVT_R_CONST) / (1 << PVT_CONV_BITS);
return 0; return 0;
default: default:
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment