Commit 24b4e07d authored by Laurent Pinchart's avatar Laurent Pinchart

clocksource: sh_cmt: Rename clock to "fck" in the non-legacy case

The sh_cmt driver gets the CMT functional clock using a connection ID of
"cmt_fck". While all SH SoCs create clock lookup entries with a NULL
device ID and a "cmt_fck" connection ID, the ARM SoCs use the device ID
only with a NULL connection ID. This works on legacy platforms but will
break on ARM with DT boot.

Fix the situation by using a connection ID of "fck" in the non-legacy
platform data case. Clock lookup entries will be renamed to use the
device ID as well as the connection ID as platforms get moved to new
platform data. The legacy code will eventually be dropped, leaving us
with device ID based clock lookup, compatible with DT boot.
Signed-off-by: default avatarLaurent Pinchart <laurent.pinchart+renesas@ideasonboard.com>
parent 81b3b271
......@@ -1007,7 +1007,7 @@ static int sh_cmt_setup(struct sh_cmt_device *cmt, struct platform_device *pdev)
cmt->legacy = cmt->info ? false : true;
/* Get hold of clock. */
cmt->clk = clk_get(&cmt->pdev->dev, "cmt_fck");
cmt->clk = clk_get(&cmt->pdev->dev, cmt->legacy ? "cmt_fck" : "fck");
if (IS_ERR(cmt->clk)) {
dev_err(&cmt->pdev->dev, "cannot get clock\n");
return PTR_ERR(cmt->clk);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment