mmc: sdio: fix runtime PM path during driver removal
After commit e1866b33 "PM / Runtime: Rework runtime PM handling during driver removal" was introduced, the driver core stopped incrementing the runtime PM usage counter of the device during the invocation of the ->remove() callback. This indirectly broke SDIO's runtime PM path during driver removal, because no one calls _put_sync() anymore after ->remove() completes. This means that the power of runtime-PM-managed SDIO cards is kept high after their driver is removed (even if it was powered down beforehand). Fix that by directly calling _put_sync() when the last usage counter is downref'ed by the SDIO bus. Reported-and-tested-by: Daniel Drake <dsd@laptop.org> Signed-off-by: Ohad Ben-Cohen <ohad@wizery.com> Signed-off-by: Chris Ball <cjb@laptop.org>