scripts/get_abi.pl: avoid creating duplicate names
The file the Documentation/ABI/testing/sysfs-class-power has voltage_min, voltage_max and voltage_now symbols duplicated. They are defined first for "General Properties" and then for "USB Properties". This cause those warnings: get_abi.pl rest --dir $srctree/Documentation/ABI/testing:26933: WARNING: Duplicate explicit target name: "abi_sys_class_power_supply_supply_name_voltage_max". get_abi.pl rest --dir $srctree/Documentation/ABI/testing:26968: WARNING: Duplicate explicit target name: "abi_sys_class_power_supply_supply_name_voltage_min". get_abi.pl rest --dir $srctree/Documentation/ABI/testing:27008: WARNING: Duplicate explicit target name: "abi_sys_class_power_supply_supply_name_voltage_now". And, as the references are not valid, it will also generate warnings about links to undefined references. Fix it by storing labels into a hash table and, when a duplicated one is found, appending random characters at the end. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>