iio: magnetometer: mag3110: Add ability to run in continuous mode
Adds the ability to run the Mag3110 in continuous mode to speed up the sampling rate. Depending on the sampling rate requested the device can be put in or out of continuous mode automatically. Shifting out of continuous mode requires a potential 1 / ODR wait which is also implemented. Modified the sleep method when data is not ready to allow for sampling > 50sps to work. Signed-off-by: Richard Tresidder <rtresidd@electromag.com.au> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>