Commit 3ae5f066 authored by Tony Lindgren's avatar Tony Lindgren Committed by Sebastian Reichel

power: supply: cpcap-charger: Fix charge voltage configuration

We have the charge voltage wrong, it should be 4.35V instead of 4.2V.
This will cause the battery to never get fully charged.

I noticed this when looking at the Andoid kernel battery and charger
status for a fully charged battery:

POWER_SUPPLY_VOLTAGE_NOW=4351000

Also the battery on droid 4 says "4.35, 1735/1785mAh (min/typ),
6.6/6.8 Wh (min/typ)". Presumably the 4.35 on the battery is the
charge voltage.

And finally, on Android the CPCAP CRM register is set to 0x03b5 where
the b is the charge voltage.

Let's fix the charge voltage define and update the charge configuration
to use the 4.35V setting.

Fixes: 0c9888e3 ("power: supply: cpcap-charger: Add minimal
CPCAP PMIC battery charger")
Cc: Marcel Partap <mpartap@gmx.net>
Cc: Michael Scott <michael.scott@linaro.org>
Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.co.uk>
parent 4f700a52
......@@ -76,7 +76,7 @@
#define CPCAP_REG_CRM_VCHRG_4V30 CPCAP_REG_CRM_VCHRG(0x8)
#define CPCAP_REG_CRM_VCHRG_4V32 CPCAP_REG_CRM_VCHRG(0x9)
#define CPCAP_REG_CRM_VCHRG_4V34 CPCAP_REG_CRM_VCHRG(0xa)
#define CPCAP_REG_CRM_VCHRG_4V36 CPCAP_REG_CRM_VCHRG(0xb)
#define CPCAP_REG_CRM_VCHRG_4V35 CPCAP_REG_CRM_VCHRG(0xb)
#define CPCAP_REG_CRM_VCHRG_4V38 CPCAP_REG_CRM_VCHRG(0xc)
#define CPCAP_REG_CRM_VCHRG_4V40 CPCAP_REG_CRM_VCHRG(0xd)
#define CPCAP_REG_CRM_VCHRG_4V42 CPCAP_REG_CRM_VCHRG(0xe)
......@@ -433,7 +433,7 @@ static void cpcap_usb_detect(struct work_struct *work)
max_current = CPCAP_REG_CRM_ICHRG_0A528;
error = cpcap_charger_set_state(ddata,
CPCAP_REG_CRM_VCHRG_4V20,
CPCAP_REG_CRM_VCHRG_4V35,
max_current,
CPCAP_REG_CRM_TR_0A72);
if (error)
......