ASoC: rsnd: rsnd_get_dalign() needs to care SSIU, not SSI
SSIU was controlled by SSI before, but commit c7f69ab5("ASoC: rsnd: use mod base common method on SSIU") separated it into ssiu.c But, it didn't care about rsnd_get_dalign() for judging SSI_BUSIF_DALIGN register value which changes the stream data order. This function will be called from cmd/src/ssiu now, but current code still cares ssi, not ssiu. This patch fix it up Signed-off-by: Kuninori Morimoto <kuninori.morimoto.gx@renesas.com> Tested-by: Hiroyuki Yokoyama <hiroyuki.yokoyama.vx@renesas.com> Signed-off-by: Mark Brown <broonie@kernel.org>