serial: sh-sci: Do not start transfers from sci_startup()
FIFO reset is done in sci_reset(), called from sci_set_termios(), while sci_start_tx() and sci_start_rx() are called before, from sci_startup(). However, starting transfers before the UART's FIFOs have been reset may cause reading of stale data. Remove the calls to sci_start_tx() and sci_start_rx() from sci_startup() to fix this. Transfers are still started when needed: - sci_start_rx() is called from sci_set_termios() after FIFO reset, if the CREAD flag is set, - sci_start_tx() is called from uart_change_speed() immediately thereafter, if transmission is enabled. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>