thermal: rockhip: fix setting thermal shutdown polarity
When requested thermal shutdown signal polarity is low we need to make sure that the bit representing high level of signal is reset, and not set all other bits in that register. Also rename TSADCV2_INT_PD_CLEAR to TSADCV2_INT_PD_CLEAR_MASK to better reflect its nature. Acked-by: Caesar Wang <wxt@rock-chips.com> Signed-off-by: Dmitry Torokhov <dtor@chromium.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>