Commit 47cbb046 authored by AngeloGioacchino Del Regno's avatar AngeloGioacchino Del Regno Committed by Daniel Lezcano

thermal/drivers/mediatek: Add temperature constraints to validate read

The AUXADC thermal v1 allows reading temperature range between -20°C to
150°C and any value out of this range is invalid.

Add new definitions for MT8173_TEMP_{MIN_MAX} and a new small helper
mtk_thermal_temp_is_valid() to check if new readings are in range: if
not, we tell to the API that the reading is invalid by returning
THERMAL_TEMP_INVALID.

It was chosen to introduce the helper function because, even though this
temperature range is realistically ok for all, it comes from a downstream
kernel driver for version 1, but here we also support v2 and v3 which may
may have wider constraints.
Signed-off-by: default avatarAngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>
Signed-off-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20230419061146.22246-3-angelogioacchino.delregno@collabora.com
parent 0a677eea
......@@ -116,6 +116,10 @@
/* The calibration coefficient of sensor */
#define MT8173_CALIBRATION 165
/* Valid temperatures range */
#define MT8173_TEMP_MIN -20000
#define MT8173_TEMP_MAX 150000
/*
* Layout of the fuses providing the calibration data
* These macros could be used for MT8183, MT8173, MT2701, and MT2712.
......@@ -689,6 +693,11 @@ static const struct mtk_thermal_data mt7986_thermal_data = {
.version = MTK_THERMAL_V3,
};
static bool mtk_thermal_temp_is_valid(int temp)
{
return (temp >= MT8173_TEMP_MIN) && (temp <= MT8173_TEMP_MAX);
}
/**
* raw_to_mcelsius_v1 - convert a raw ADC value to mcelsius
* @mt: The thermal controller
......@@ -815,14 +824,17 @@ static int mtk_thermal_bank_temperature(struct mtk_thermal_bank *bank)
temp = mt->raw_to_mcelsius(
mt, conf->bank_data[bank->id].sensors[i], raw);
/*
* The first read of a sensor often contains very high bogus
* temperature value. Filter these out so that the system does
* not immediately shut down.
* Depending on the filt/sen intervals and ADC polling time,
* we may need up to 60 milliseconds after initialization: this
* will result in the first reading containing an out of range
* temperature value.
* Validate the reading to both address the aforementioned issue
* and to eventually avoid bogus readings during runtime in the
* event that the AUXADC gets unstable due to high EMI, etc.
*/
if (temp > 200000)
temp = 0;
if (!mtk_thermal_temp_is_valid(temp))
temp = THERMAL_TEMP_INVALID;
if (temp > max)
max = temp;
......