staging:iio:ad7606: fix voltage scales

Fixes commit 17be2a29 ("staging: iio:
ad7606: replace range/range_available with corresponding scale").

The AD7606 devices don't have a 2.5V voltage range, they have 5V & 10V
voltage range, which is selectable via the `gpio_range` descriptor.

The scales also seem to have been miscomputed, because when they were
applied to the raw values, the results differ from the expected values.
After checking the ADC transfer function in the datasheet, these were
re-computed.
Signed-off-by: default avatarAlexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent 6029b7ac
......@@ -26,9 +26,12 @@
#include "ad7606.h"
/* Scales are computed as 2.5/2**16 and 5/2**16 respectively */
/*
* Scales are computed as 5000/32768 and 10000/32768 respectively,
* so that when applied to the raw values they provide mV values
*/
static const unsigned int scale_avail[2][2] = {
{0, 38147}, {0, 76294}
{0, 152588}, {0, 305176}
};