iio: light: opt3001: add missing full-scale range value
The opt3001 driver uses predetermined full-scale range values to determine what exponent to use for event trigger threshold values. The problem is that one of the values specified in the datasheet is missing from the implementation. This causes larger values to be scaled down to an incorrect exponent, effectively reducing the maximum settable threshold value by a factor of 2. Add missing full-scale range array value. Fixes: 94a9b7b1 ("iio: light: add support for TI's opt3001 light sensor") Signed-off-by: Emil Gedenryd <emil.gedenryd@axis.com> Cc: <Stable@vger.kernel.org> Link: https://patch.msgid.link/20240913-add_opt3002-v2-1-69e04f840360@axis.comSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>