iio: adc: ti-ads1015: remove unnecessary config register update
The ti-ads1015 driver has eight iio voltage channels and each iio channel can hold own scale information. The ADS1015 device only have a single config register which contains an input multiplexer selection, PGA and data rate settings. So the driver should load the correct settings when the input multiplexer selection is changed. However, regardless of which channlel is currently selected, changing any iio channel's scale information immediately overwrites the current PGA setting in the config register. It is harmless because the correct PGA settings are reloaded just before getting adc result anyway. But it is unnecessary register update and should be removed. Cc: Daniel Baluta <daniel.baluta@gmail.com> Cc: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>