Commit 5c8e9046 authored by Yevgeny Petrilin's avatar Yevgeny Petrilin Committed by David S. Miller

net/mlx4_en: Set correct port parameters during device initialization

Set valid port parameters: MTU and flow control configuration when
configuring the port during HW device initialization,
prior to the net device open() being called.
Using  invalid parameters (such as all zeros)
could lead to bad firmware behavior.
Signed-off-by: default avatarYevgeny Petrilin <yevgenyp@mellanox.co.il>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 6de0298e
......@@ -1204,9 +1204,11 @@ int mlx4_en_init_netdev(struct mlx4_en_dev *mdev, int port,
en_warn(priv, "Using %d RX rings\n", prof->rx_ring_num);
/* Configure port */
mlx4_en_calc_rx_buf(dev);
err = mlx4_SET_PORT_general(mdev->dev, priv->port,
MLX4_EN_MIN_MTU,
0, 0, 0, 0);
priv->rx_skb_size + ETH_FCS_LEN,
prof->tx_pause, prof->tx_ppp,
prof->rx_pause, prof->rx_ppp);
if (err) {
en_err(priv, "Failed setting port general configurations "
"for port %d, with error %d\n", priv->port, err);
......