Commit 601c2a54 authored by Sebastian Reichel's avatar Sebastian Reichel

power: supply: core: add POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED

Some battery fuel gauges know when the battery needs to
be recalibrated before providing usable values. This
should be reported via the health property.
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent feabe49e
......@@ -205,7 +205,7 @@ Description:
Valid values: "Unknown", "Good", "Overheat", "Dead",
"Over voltage", "Unspecified failure", "Cold",
"Watchdog timer expire", "Safety timer expire",
"Over current"
"Over current", "Calibration required"
What: /sys/class/power_supply/<supply_name>/precharge_current
Date: June 2017
......
......@@ -100,6 +100,7 @@ static const char * const POWER_SUPPLY_HEALTH_TEXT[] = {
[POWER_SUPPLY_HEALTH_WATCHDOG_TIMER_EXPIRE] = "Watchdog timer expire",
[POWER_SUPPLY_HEALTH_SAFETY_TIMER_EXPIRE] = "Safety timer expire",
[POWER_SUPPLY_HEALTH_OVERCURRENT] = "Over current",
[POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED] = "Calibration required",
};
static const char * const POWER_SUPPLY_TECHNOLOGY_TEXT[] = {
......
......@@ -61,6 +61,7 @@ enum {
POWER_SUPPLY_HEALTH_WATCHDOG_TIMER_EXPIRE,
POWER_SUPPLY_HEALTH_SAFETY_TIMER_EXPIRE,
POWER_SUPPLY_HEALTH_OVERCURRENT,
POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED,
};
enum {
......
Markdown is supported