USB: cdc-acm: restore capability check order
commit b401f8c4 ("USB: cdc-acm: fix rounding error in TIOCSSERIAL") introduced a regression by changing the order of capability and close settings change checks. When running with CAP_SYS_ADMIN setting the close settings to the values already set resulted in -EOPNOTSUPP. Fix this by changing the check order back to how it was before. Fixes: b401f8c4 ("USB: cdc-acm: fix rounding error in TIOCSSERIAL") Cc: Anthony Mallet <anthony.mallet@laas.fr> Cc: stable <stable@vger.kernel.org> Cc: Oliver Neukum <oneukum@suse.com> Signed-off-by: Matthias Reichl <hias@horus.com> Link: https://lore.kernel.org/r/20200327150350.3657-1-hias@horus.comSigned-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>