i40e: Fix I40E_FLAG_VF_VLAN_PRUNING value
Commit c87c938f ("i40e: Add VF VLAN pruning") added new PF flag I40E_FLAG_VF_VLAN_PRUNING but its value collides with existing I40E_FLAG_TOTAL_PORT_SHUTDOWN_ENABLED flag. Move the affected flag at the end of the flags and fix its value. Reproducer: [root@cnb-03 ~]# ethtool --set-priv-flags enp2s0f0np0 link-down-on-close on [root@cnb-03 ~]# ethtool --set-priv-flags enp2s0f0np0 vf-vlan-pruning on [root@cnb-03 ~]# ethtool --set-priv-flags enp2s0f0np0 link-down-on-close off [ 6323.142585] i40e 0000:02:00.0: Setting link-down-on-close not supported on this port (because total-port-shutdown is enabled) netlink error: Operation not supported [root@cnb-03 ~]# ethtool --set-priv-flags enp2s0f0np0 vf-vlan-pruning off [root@cnb-03 ~]# ethtool --set-priv-flags enp2s0f0np0 link-down-on-close off The link-down-on-close flag cannot be modified after setting vf-vlan-pruning because vf-vlan-pruning shares the same bit with total-port-shutdown flag that prevents any modification of link-down-on-close flag. Fixes: c87c938f ("i40e: Add VF VLAN pruning") Cc: Mateusz Palczewski <mateusz.palczewski@intel.com> Cc: Simon Horman <horms@kernel.org> Signed-off-by: Ivan Vecera <ivecera@redhat.com> Reviewed-by: Jacob Keller <jacob.e.keller@intel.com> Tested-by: Pucha Himasekhar Reddy <himasekharx.reddy.pucha@intel.com> (A Contingent worker at Intel) Signed-off-by: David S. Miller <davem@davemloft.net>