clk: samsung: clk-pll: Implement pll0831x PLL type
pll0831x PLL is used in Exynos850 SoC for top-level fractional PLLs. The code was derived from very similar pll36xx type, with next differences: 1. Lock time for pll0831x is 500*P_DIV, when for pll36xx it's 3000*P_DIV 2. It's not suggested in Exynos850 TRM that S_DIV change doesn't require performing PLL lock procedure (which is done in pll36xx implementation) 3. The offset from PMS-values register to K-value register is 0x8 for pll0831x, when for pll36xx it's 0x4 When defining pll0831x type, CON3 register offset should be provided as a "con" parameter of PLL() macro, like this: PLL(pll_0831x, 0, "fout_mmc_pll", "oscclk", PLL_LOCKTIME_PLL_MMC, PLL_CON3_PLL_MMC, pll0831x_26mhz_tbl), To define PLL rates table, one can use PLL_36XX_RATE() macro, e.g.: PLL_36XX_RATE(26 * MHZ, 799999877, 31, 1, 0, -15124) as it's completely appropriate for pl0831x type and there is no sense in duplicating that. If bit #1 (MANUAL_PLL_CTRL) is not set in CON1 register, it won't be possible to set new rate, with next error showing in kernel log: Could not lock PLL fout_mmc_pll That can happen for example if bootloader clears that bit beforehand. PLL driver doesn't account for that, so if MANUAL_PLL_CTRL bit was cleared, it's assumed it was done for a reason and it shouldn't be possible to change that PLL's rate at all. Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com> Acked-by: Chanwoo Choi <cw00.choi@samsung.com> Link: https://lore.kernel.org/r/20211008154352.19519-3-semen.protsenko@linaro.orgSigned-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Showing
Please register or sign in to comment