Commit 6b4814a9 authored by Steve Twiss's avatar Steve Twiss Committed by Lee Jones

mfd: da9063: Fix OTP control register names to match datasheets for DA9063/63L

Mismatch between what is found in the Datasheets for DA9063 and DA9063L
provided by Dialog Semiconductor, and the register names provided in the
MFD registers file. The changes are for the OTP (one-time-programming)
control registers. The two naming errors are OPT instead of OTP, and
COUNT instead of CONT (i.e. control).

Cc: Stable <stable@vger.kernel.org>
Signed-off-by: default avatarSteve Twiss <stwiss.opensource@diasemi.com>
Signed-off-by: default avatarLee Jones <lee.jones@linaro.org>
parent 9e364e87
......@@ -210,9 +210,9 @@
/* DA9063 Configuration registers */
/* OTP */
#define DA9063_REG_OPT_COUNT 0x101
#define DA9063_REG_OPT_ADDR 0x102
#define DA9063_REG_OPT_DATA 0x103
#define DA9063_REG_OTP_CONT 0x101
#define DA9063_REG_OTP_ADDR 0x102
#define DA9063_REG_OTP_DATA 0x103
/* Customer Trim and Configuration */
#define DA9063_REG_T_OFFSET 0x104
......