Commit 6db50bb6 authored by Marc Zyngier's avatar Marc Zyngier Committed by Daniel Lezcano

clocksource: sunxi: Stop timer from ticking before enabling interrupts

The sun4i timer can still be ticking when we enable the interrupt.
If another timer is actually used (A7 architected timer, for example),
odds are that the interrupt will eventually fire with the event_handler
pointer being NULL.

The obvious fix it to stop the timer before registering the interrupt.

Observed and tested on sun7i (cubietruck).

Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: default avatarMaxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: default avatarMarc Zyngier <marc.zyngier@arm.com>
Signed-off-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
parent 4c4b0532
......@@ -179,6 +179,9 @@ static void __init sun4i_timer_init(struct device_node *node)
writel(TIMER_CTL_CLK_SRC(TIMER_CTL_CLK_SRC_OSC24M),
timer_base + TIMER_CTL_REG(0));
/* Make sure timer is stopped before playing with interrupts */
sun4i_clkevt_time_stop(0);
ret = setup_irq(irq, &sun4i_timer_irq);
if (ret)
pr_warn("failed to setup irq %d\n", irq);
......