Commit 70052917 authored by Peter Feuerer's avatar Peter Feuerer Committed by Len Brown

acerhdf: return temperature in milidegree instead of degree

Return temperature in milidegree instead of degree, as sysfs-api requires
the temperature in milidegree.
Signed-off-by: default avatarPeter Feuerer <peter@piie.net>
Tested-by: default avatarBorislav Petkov <petkovbb@gmail.com>
Cc: Andreas Mohr <andi@lisas.de>
Signed-off-by: default avatarAndrew Morton <akpm@linux-foundation.org>
Signed-off-by: default avatarLen Brown <len.brown@intel.com>
parent a8a8a669
......@@ -52,7 +52,7 @@
*/
#undef START_IN_KERNEL_MODE
#define DRV_VER "0.5.17"
#define DRV_VER "0.5.18"
/*
* According to the Atom N270 datasheet,
......@@ -61,7 +61,7 @@
* measured by the on-die thermal monitor are within 0 <= Tj <= 90. So,
* assume 89°C is critical temperature.
*/
#define ACERHDF_TEMP_CRIT 89
#define ACERHDF_TEMP_CRIT 89000
#define ACERHDF_FAN_OFF 0
#define ACERHDF_FAN_AUTO 1
......@@ -69,7 +69,7 @@
* No matter what value the user puts into the fanon variable, turn on the fan
* at 80 degree Celsius to prevent hardware damage
*/
#define ACERHDF_MAX_FANON 80
#define ACERHDF_MAX_FANON 80000
/*
* Maximum interval between two temperature checks is 15 seconds, as the die
......@@ -85,8 +85,8 @@ static int kernelmode;
#endif
static unsigned int interval = 10;
static unsigned int fanon = 63;
static unsigned int fanoff = 58;
static unsigned int fanon = 63000;
static unsigned int fanoff = 58000;
static unsigned int verbose;
static unsigned int fanstate = ACERHDF_FAN_AUTO;
static char force_bios[16];
......@@ -171,7 +171,7 @@ static int acerhdf_get_temp(int *temp)
if (ec_read(bios_cfg->tempreg, &read_temp))
return -EINVAL;
*temp = read_temp;
*temp = read_temp * 1000;
return 0;
}
......