iio: mlx90614: Add MLX90615 support
Add support for MLX90615 Infra Red Thermometer, which seems to be the predecesor of MLX90614 . There are significant differences in the register layout compared to MLX90614, but the functionality of the device is virtually identical. The following differences have been identified: - RAM/EEPROM/SLEEP access opcodes are different - RAM/EEPROM registers are at different offsets - EEPROM emissivity and configuration registers are at different offsets - EEPROM configuration register bits are shuffled around - EEPROM emissivity settings are 14 bit on MLX90615 , 16 bit on MLX90614 - MLX90615 can only ever support one sensor, MLX90614 could support two - FIR filter is set to fixed settings on MLX90615 - IIR filter coefficients are different This patch fills in the MLX90615 specific description and quirk handling. The IIR filter coefficients were provided by Melexis as follows: 0b0000 - Forbidden value 0b0001 - 100% - settling time = refresh rate = 205ms (around 5Hz) 0b0010 - 50% - settling time = 2050ms (around 0.5Hz) 0b0011 - 33% - settling time = 36900ms (around 0.3Hz) 0b0100 - 25% - settling time = 5125ms (around 0.2Hz) 0b0101 - 20% - settling time = 6355ms (around 0.15Hz) 0b0110 - 17% - settling time = 7790ms (around 0.13Hz) 0b0111 - 14% - settling time = 9225ms (around 0.1Hz) Signed-off-by: Marek Vasut <marex@denx.de> Acked-by: Crt Mori <cmo@melexis.com> Link: https://lore.kernel.org/r/20230510102251.10118-6-marex@denx.deSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>