regulator: twl: Fix checking voltage range in twl6030smps_set_voltage()
The voltage selection logic is supposed to find the samllest voltage falls within specified range. When using equation to calculate vsel, we need to ensure the requested min_uV meet the range of using the equation. Otherwise we may select a voltage that is out of specified range. For example, in the case vsel = 62 means select voltage of 2100000uV. What we want is to ensure the requested min_uV <= 2100000 rather than checking max_uV >= 2100000. And this also means in the case min_uV > 2100000, vsel = 62 does not meet the request. Also calling twl6030smps_list_voltage() for all cases to ensure the selected voltage still in bounds. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>