Commit 784adeb3 authored by Yassine Oudjana's avatar Yassine Oudjana Committed by Viresh Kumar

dt-bindings: opp: qcom-opp: Convert to DT schema

Convert qcom-opp.txt to DT schema format.
Signed-off-by: default avatarYassine Oudjana <y.oudjana@protonmail.com>
Reviewed-by: default avatarRob Herring <robh@kernel.org>
Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
parent 8188eaf4
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/opp/opp-v2-qcom-level.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: Qualcomm OPP bindings to describe OPP nodes.
maintainers:
- Niklas Cassel <nks@flawful.org>
allOf:
- $ref: opp-v2-base.yaml#
properties:
compatible:
const: operating-points-v2-qcom-level
patternProperties:
'^opp-?[0-9]+$':
type: object
properties:
opp-level: true
qcom,opp-fuse-level:
description: |
A positive value representing the fuse corner/level associated with
this OPP node. Sometimes several corners/levels shares a certain fuse
corner/level. A fuse corner/level contains e.g. ref uV, min uV,
and max uV.
$ref: /schemas/types.yaml#/definitions/uint32
required:
- opp-level
- qcom,opp-fuse-level
required:
- compatible
additionalProperties: false
examples:
- |
cpr_opp_table: opp-table-cpr {
compatible = "operating-points-v2-qcom-level";
cpr_opp1: opp1 {
opp-level = <1>;
qcom,opp-fuse-level = <1>;
};
cpr_opp2: opp2 {
opp-level = <2>;
qcom,opp-fuse-level = <2>;
};
cpr_opp3: opp3 {
opp-level = <3>;
qcom,opp-fuse-level = <3>;
};
};
Qualcomm OPP bindings to describe OPP nodes
The bindings are based on top of the operating-points-v2 bindings
described in Documentation/devicetree/bindings/opp/opp-v2-base.yaml
Additional properties are described below.
* OPP Table Node
Required properties:
- compatible: Allow OPPs to express their compatibility. It should be:
"operating-points-v2-qcom-level"
* OPP Node
Required properties:
- qcom,opp-fuse-level: A positive value representing the fuse corner/level
associated with this OPP node. Sometimes several corners/levels shares
a certain fuse corner/level. A fuse corner/level contains e.g. ref uV,
min uV, and max uV.
Markdown is supported