drm/panel: st7701: Fix AVCL calculation
The AVCL register, according to the datasheet, comes in increments of -0.2v between -4.4v (represented by 0x0) to -5.0v (represented by 0x3). The current calculation is done by adding the defined AVCL value in mV to -4400 and then dividing by 200 to get the register value. Unfortunately if I subtract -4400 from -4400 I get -8800, which divided by 200 gives me -44. If I instead subtract -4400 from -4400 I get 0, which divided by 200 gives me 0. Based on the datasheet this is the expected register value. Fixes: 83b7a8e7 ("drm/panel/panel-sitronix-st7701: Parametrize voltage and timing") Signed-off-by: Chris Morgan <macromorgan@hotmail.com> Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org> Link: https://lore.kernel.org/r/20231208154847.130615-2-macroalpha82@gmail.comSigned-off-by: Neil Armstrong <neil.armstrong@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20231208154847.130615-2-macroalpha82@gmail.com