MIPS: scall64-o32: Fix indirect syscall number load
Commit 4c21b8fd (MIPS: seccomp: Handle indirect system calls (o32)) added indirect syscall detection for O32 processes running on MIPS64, but it did not work correctly for big endian kernel/processes. The reason is that the syscall number is loaded from ARG1 using the lw instruction while this is a 64-bit value, so zero is loaded instead of the syscall number. Fix the code by using the ld instruction instead. When running a 32-bit processes on a 64 bit CPU, the values are properly sign-extended, so it ensures the value passed to syscall_trace_enter is correct. Recent systemd versions with seccomp enabled whitelist the getpid syscall for their internal processes (e.g. systemd-journald), but call it through syscall(SYS_getpid). This fix therefore allows O32 big endian systems with a 64-bit kernel to run recent systemd versions. Signed-off-by: Aurelien Jarno <aurelien@aurel32.net> Cc: <stable@vger.kernel.org> # v3.15+ Reviewed-by: Philippe Mathieu-Daudé <f4bug@amsat.org> Signed-off-by: Paul Burton <paul.burton@mips.com> Cc: Ralf Baechle <ralf@linux-mips.org> Cc: James Hogan <jhogan@kernel.org> Cc: linux-mips@vger.kernel.org Cc: linux-kernel@vger.kernel.org