dt-bindings: iio: pressure: honeywell,mprls0025pa.yaml improvements
Define enum inside the honeywell,transfer-function property block. Set the correct irq edge in the example block. Based on the datasheet, in table 13 on page 11: "End-of-conversion indicator: This pin is set high when a measurement and calculation have been completed and the data is ready to be clocked out" Add description on End-of-conversion interrupt. Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Co-developed-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro> Link: https://lore.kernel.org/r/20231229092445.30180-2-petre.rodan@subdimension.roSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>