Commit 7c852375 authored by Marek Vasut's avatar Marek Vasut Committed by Sebastian Reichel

power: supply: bq25890: Clean up POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE

Clean up misuse of POWER_SUPPLY_PROP_VOLTAGE,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX
and POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE
and document what exactly each value means.

The POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE content is newly read
back from hardware, while POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX
is reported as the maximum value set in DT.

The POWER_SUPPLY_PROP_VOLTAGE is newly used to report immediate value
of battery voltage V_BAT, which is what this property was intended to
report and which has been thus far misused to report the charger chip
output voltage V_SYS.

The V_SYS is no longer reported as there is currently no suitable
property to report V_SYS. V_SYS reporting will be reinstated in
subsequent patch.
Signed-off-by: default avatarMarek Vasut <marex@denx.de>
Reviewed-by: default avatarHans de Goede <hdegoede@redhat.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 8327a8ab
......@@ -529,24 +529,6 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
break;
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE:
if (!state.online) {
val->intval = 0;
break;
}
ret = bq25890_field_read(bq, F_BATV); /* read measured value */
if (ret < 0)
return ret;
/* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */
val->intval = 2304000 + ret * 20000;
break;
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX:
val->intval = bq25890_find_val(bq->init_data.vreg, TBL_VREG);
break;
case POWER_SUPPLY_PROP_PRECHARGE_CURRENT:
val->intval = bq25890_find_val(bq->init_data.iprechg, TBL_ITERM);
break;
......@@ -563,15 +545,6 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
val->intval = bq25890_find_val(ret, TBL_IINLIM);
break;
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
ret = bq25890_field_read(bq, F_SYSV); /* read measured value */
if (ret < 0)
return ret;
/* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */
val->intval = 2304000 + ret * 20000;
break;
case POWER_SUPPLY_PROP_CURRENT_NOW: /* I_BAT now */
/*
* This is ADC-sampled immediate charge current supplied
......@@ -628,6 +601,51 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
val->intval = bq25890_find_val(bq->init_data.ichg, TBL_ICHG);
break;
case POWER_SUPPLY_PROP_VOLTAGE_NOW: /* V_BAT now */
/*
* This is ADC-sampled immediate charge voltage supplied
* from charger to battery. The property name is confusing,
* for clarification refer to:
* Documentation/ABI/testing/sysfs-class-power
* /sys/class/power_supply/<supply_name>/voltage_now
*/
ret = bq25890_field_read(bq, F_BATV); /* read measured value */
if (ret < 0)
return ret;
/* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */
val->intval = 2304000 + ret * 20000;
break;
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE: /* V_BAT user limit */
/*
* This is user-configured constant charge voltage supplied
* from charger to battery in second phase of charging, when
* battery voltage reached constant charge voltage.
*
* This value reflects the current hardware setting.
*
* The POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX is the
* maximum value of this property.
*/
ret = bq25890_field_read(bq, F_VREG);
if (ret < 0)
return ret;
val->intval = bq25890_find_val(ret, TBL_VREG);
break;
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX: /* V_BAT max */
/*
* This is maximum allowed constant charge voltage supplied
* from charger to battery in second phase of charging, when
* battery voltage reached constant charge voltage.
*
* This value is constant for each battery and set from DT.
*/
val->intval = bq25890_find_val(bq->init_data.vreg, TBL_VREG);
break;
case POWER_SUPPLY_PROP_TEMP:
ret = bq25890_field_read(bq, F_TSPCT);
if (ret < 0)
......