net: hns3: Fixes the init of the VALID BD info in the descriptor
RX Buffer Descriptor contains a VALID bit which indicates if the BD is valid and has some data. This field is set by HNS3 hardware to intimate the driver of some valid data present in the BD. nd should be reset by the driver when BD is being used again. In the existing code this bit was not being (re-)initialized properly and hence was causing problems. Fixes: 76ad4f0e ("net: hns3: Add support of HNS3 Ethernet Driver for hip08 SoC") Signed-off-by: Fuyun Liang <liangfuyun1@huawei.com> Signed-off-by: Peng Li <lipeng321@huawei.com> Signed-off-by: Salil Mehta <salil.mehta@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Showing
Please register or sign in to comment