net: dsa: sja1105: block FDB accesses that are concurrent with a switch reset
Currently, when we add the first sja1105 port to a bridge with vlan_filtering 1, then we sometimes see this output: sja1105 spi2.2: port 4 failed to read back entry for be:79:b4:9e:9e:96 vid 3088: -ENOENT sja1105 spi2.2: Reset switch and programmed static config. Reason: VLAN filtering sja1105 spi2.2: port 0 failed to add be:79:b4:9e:9e:96 vid 0 to fdb: -2 It is because sja1105_fdb_add() runs from the dsa_owq which is no longer serialized with switch resets since it dropped the rtnl_lock() in the blamed commit. Either performing the FDB accesses before the reset, or after the reset, is equally fine, because sja1105_static_fdb_change() backs up those changes in the static config, but FDB access during reset isn't ok. Make sja1105_static_config_reload() take the fdb_lock to fix that. Fixes: 0faf890f ("net: dsa: drop rtnl_lock from dsa_slave_switchdev_event_work") Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>