mmc: omap: restore original power up/down steps
Commit e519f0bb ("ARM/mmc: Convert old mmci-omap to GPIO descriptors") moved Nokia N810 MMC power up/down from the board file into the MMC driver. The change removed some delays, and ordering without a valid reason. Restore power up/down to match the original code. This matters only on N810 where the 2nd GPIO is in use. Other boards will see an additional delay but that should be a lesser concern than omitting delays altogether. Fixes: e519f0bb ("ARM/mmc: Convert old mmci-omap to GPIO descriptors") Signed-off-by:Aaro Koskinen <aaro.koskinen@iki.fi> Message-ID: <20240223181439.1099750-6-aaro.koskinen@iki.fi> Reviewed-by:
Linus Walleij <linus.walleij@linaro.org> Acked-by:
Ulf Hansson <ulf.hansson@linaro.org> Signed-off-by:
Tony Lindgren <tony@atomide.com>