regulator: act8865: Fix act8600_sudcdc_voltage_ranges setting
[ Upstream commit f01a7beb ] The act8600_sudcdc_voltage_ranges setting does not match the datasheet. The problems in below entry: REGULATOR_LINEAR_RANGE(19000000, 191, 255, 400000), 1. The off-by-one min_sel causes wrong volatage calculation. The min_sel should be 192. 2. According to the datasheet[1] Table 7. (on page 43): The selector 248 (0b11111000) ~ 255 (0b11111111) are 41.400V. Also fix off-by-one for ACT8600_SUDCDC_VOLTAGE_NUM. [1] https://active-semi.com/wp-content/uploads/ACT8600_Datasheet.pdf Fixes: df3a950e ("regulator: act8865: Add act8600 support") Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@kernel.org> Signed-off-by: Sasha Levin <sashal@kernel.org>
Showing
Please register or sign in to comment