iio: gyro: bmg160: fix endianness when reading axes
commit 95e7ff03 upstream. For big endian platforms, reading the axes will return invalid values. The device stores each axis value in a 16 bit little endian register. The driver uses regmap_read_bulk to get the axis value, resulting in a 16 bit little endian value. This needs to be converted to cpu endianness to work on big endian platforms. Fix endianness for big endian platforms by converting the values for the axes read from little endian to cpu. This is also partially fixed in commit 82d8e5da1a33 ("iio: accel: bmg160: optimize transfers in trigger handler"). Signed-off-by: Irina Tirdea <irina.tirdea@intel.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>